Imagine you're trying to measure whether a pool table is perfectly level by rolling a ball very gently and watching which direction it drifts. But your ball has a tiny dent in it — it always curves slightly left regardless of the table's tilt. If the dent's effect is 1.5 millimeters of drift per meter, and the table's actual tilt produces only 1 millimeter of drift, you can't separate signal from artifact. Your measurement floor is the dent, not the table. Now someone carefully re-measures the dent and finds it's actually only 0.6 mm — suddenly you CAN detect that 1 mm tilt. That's what Batcheldor et al. did for NICMOS, Hubble's near-infrared camera. The "dent" is residual instrumental polarization — a systematic bias that makes the telescope itself produce a polarization signal even when looking at unpolarized light. Previous work by Ueta et al. and Batcheldor et al. had estimated this at 1.2-1.5%, which would have made it impossible to do polarimetry on targets with polarization levels around 1%. This paper shows the true floor is ≤0.6%. The committed claim: NICMOS camera 2 at 2.0 micron has an instrumental polarization upper limit of 0.6%, not 1.2-1.5% as previously reported, enabling imaging polarimetry of targets at p~1.0% with accuracy ±0.6% in polarization degree and ±15° in position angle. The category of result is instrumental calibration — not a new detector, not a new algorithm, but a precise characterization of an existing instrument's systematic error. This is genuinely important work even though it sounds mundane: a factor of 2-2.5× improvement in the instrument's effective floor changes what science the telescope can do. The ladder here is against the prior calibration by Ueta et al. and the authors' own earlier work, which placed instrumental polarization at 1.2-1.5%. That number was the community's operating assumption and it was blocking multiple General Observer (GO) programs that needed accurate polarimetry below that level. The new calibration — 0.6% upper limit — doesn't beat a competitor; it corrects the field's understanding of the instrument they already have. Ground-based polarimetric standards are the reference: the updated parallel transmission coefficients reproduce ground-based results for the calibration targets, which is the right anchor. Architecturally, this is classical astronomical calibration: observe known standards at multiple instrument orientations, solve for the instrumental Mueller matrix components (specifically the parallel transmission coefficients of the polarizing elements), and validate by recovering known polarization values. The nine-orbit HST Cycle 15 program observed three polarimetric standard sources at three spacecraft roll angles separated by ~60°, combined with archival data. The multi-roll approach is the key design choice — by rotating the entire spacecraft, you modulate the instrumental polarization signature against the sky signal, allowing separation. This is the space-telescope equivalent of rotating a polarizing filter on a lab bench, except it costs ~$90K per orbit in HST time. Integrity is strong for a calibration paper. The validation is against ground-based polarimetric standards — external, independent measurements that the authors didn't produce. The 60° roll separation is a principled choice that provides three independent orientations of the instrumental polarization vector, making the decomposition well-constrained. The authors are honest about the dominant error source: photometric repeatability of the observations limits the accuracy of the parallel transmission coefficients, which in turn dominates the uncertainty in both p and θ. They don't hide behind the 0.6% number — they explicitly state it's an upper limit, meaning the true instrumental polarization could be lower but they can't prove it with this dataset. The paper is accepted by PASP (Publications of the Astronomical Society of the Pacific), the standard venue for instrument characterization. The milestone to track: ±0.6% accuracy in p at p~1% is the current floor. Getting to ±0.3% would open up polarimetry of scattered-light disks, faint AGN hosts, and other targets where polarization signals are in the 0.5-1% range. That would require either a larger calibration campaign with more orbits to beat down the photometric repeatability noise, or a fundamentally better polarimetric instrument (which JWST's NIRCam does not have — JWST has no imaging polarimetry capability in the near-IR, making NICMOS's capability unique even in the JWST era). Getting to ±0.3% on NICMOS specifically is probably not feasible — the photometric repeatability is a hardware limit. The obvious experiment they didn't run: extending the calibration to NICMOS camera 1 (shorter wavelengths) and camera 3 (longer wavelengths). The entire paper focuses on camera 2 at 2.0 micron. My read: (a) they ran out of orbits. Nine orbits is already a significant HST allocation for calibration — expanding to all three cameras would triple the cost and the proposal may not have been approved for that scope. The camera 2 at 2.0 micron choice was likely driven by the specific GO programs that were blocked by the old calibration.