You know those retractable bollards at parking garages — the ones that sink into the ground when authorized traffic approaches but pop back up to block everyone else? This paper builds the surgical robotics equivalent. The constraint that guides a surgeon's scalpel along a safe path can now retract on command, inferred not from a button press but from the surgeon flexing their forearm muscles. The bollard knows when to get out of the way. The committed claim: an anisotropic virtual fixture whose geometry adapts in real-time based on EMG-inferred surgeon intent, enabling seamless transitions between constrained precision cutting and free tool repositioning during laparoscopic resection and dissection. This is not the first adaptive virtual fixture, but it is the first to fuse anisotropic constraint geometry with EMG-based intent detection for surgical tasks. Virtual fixtures in surgical robotics have a long pedigree — they're essentially software guardrails that constrain where a tool can move. The problem everyone knows: fixed-geometry fixtures force awkward workarounds when the surgeon needs to reposition. Previous adaptive approaches used foot pedals, voice commands, or gaze tracking. EMG is structurally different because it reads intent from the same motor system that's performing the task — no context-switching, no extra limb occupied. The anisotropic piece matters because tissue cutting is directionally asymmetric: you want tight constraint perpendicular to the cut path but freedom along it. Architecturally, this sits in the impedance-control / admittance-control family for human-robot interaction. The EMG signal from forearm muscles modulates the fixture's constraint ellipsoid in real-time — muscle contraction expands the permissible workspace or disengages the constraint entirely. The control loop runs on a standard surgical robot platform for laparoscopic tasks. The anisotropic fixture itself is defined by an ellipsoidal geometry rather than the isotropic spheres or cylinders typical of conventional virtual fixtures. Integrity check: the validation is a pilot user study using a standardized surgical training task. The paper reports significant improvements in task accuracy, movement consistency, and reductions in perceived cognitive load, effort, and frustration. But we're looking at a pilot — small sample, training phantom, not live tissue. The standardized task is a strength (reproducible), but the gap between phantom and OR is enormous. No pre-registration is mentioned, no code release stated, and the specific N of participants isn't given in the abstract. The milestone question is concrete: this works on a training phantom with healthy volunteers. The next number that matters is successful deployment in a cadaver study or animal model with experienced surgeons, probably 10-20 participants, which would take 2-3 years and an IRB/ethics approval cycle. After that, the real gate is a first-in-human feasibility trial. The field needs to demonstrate that EMG-based intent inference is robust enough that a misread contraction doesn't release the constraint at exactly the wrong moment during live surgery. The experiment they didn't run: experienced surgeons performing actual tissue dissection on cadaveric or animal models. The honest read is (a) — they ran out of access and approval. Getting surgical robot time with experienced surgeons on biological tissue requires institutional partnerships, ethics approvals, and significant budget that a pilot study typically doesn't have. This is the natural next paper, and the framework is clearly built to scale to it.