Imagine you're trying to tune a guitar in a noisy room. You can pluck a string and listen for the pitch, but the room noise drowns out the note after a fraction of a second. A better microphone (a quantum state with more sensitivity) picks up more detail per instant — but it also picks up more noise, so it dies faster. The conventional wisdom says the better mic doesn't help because you lose it sooner. What this paper does is record thousands of short, high-quality snippets with the better mic and stitch them together into a long, coherent recording — one where the pitch precision keeps improving as T^{-3/2}, not T^{-1/2}, with no sign of stopping. The committed claim: by embedding Fock-state quantum enhancement inside a Qdyne (quantum heterodyne) protocol on a trapped calcium-40 ion, you can sustain metrological advantage indefinitely — the quantum gain per short interrogation cycle accumulates across total measurement time T, scaling as T^{-3/2}. This is the first demonstration of Qdyne outside solid-state spin-defect systems (NV centers in diamond), and the first to show persistent quantum-enhanced frequency sensing at this timescale. The architecture is elegant in its modularity. Qdyne works by correlating sequential short measurements against a stable local oscillator, building phase coherence across measurements rather than within a single coherence window. The key insight is that Fock states (specifically n=3 here) provide enhanced phase sensitivity per interrogation shot — Fisher information scales as 2n+1 — and since each shot is kept short (within the dephasing time), decoherence never eats the quantum advantage. The total precision then inherits both the T^{-3/2} Qdyne scaling AND the per-shot Fock enhancement. The quantum harmonic oscillator also acts as a frequency mixer, pushing operational bandwidth past 1 GHz — two orders of magnitude above pulsed dynamical-decoupling ceilings. The ladder here is well-constructed. The authors compare their n=3 Fock state against the n=0 vacuum state (the ground state of the same oscillator — the natural classical-equivalent baseline for this system). The measured quantum-enhanced gain is 7.1 ± 1.0 dB, matching Fisher information predictions of 7 dB for n=3. Frequency precision reaches 0.5 μHz on an 86 MHz carrier, yielding fractional precision of ~6×10^{-15}. The comparison is honest because the n=0 baseline uses the identical apparatus, protocol, and analysis chain — the only variable is the quantum state preparation. This is the right control. Integrity is strong for a first-demonstration paper. This is a real physical experiment on a real trapped ion, not a simulation. The agreement between measured gain (7.1 dB) and Fisher information prediction (7 dB) serves as an internal consistency check. The T^{-3/2} scaling persists over seven orders of magnitude in measurement time beyond the dephasing limit, which is a powerful self-consistency argument — if the method were flawed, deviation would appear long before 10^7 coherence times. No pre-registration, but the benchmark (Fisher information scaling) is a well-established theoretical prediction, not a post-hoc target. The milestone trajectory points toward nanoscale NMR and quantum logic spectroscopy. Current NV-center Qdyne implementations operate below ~10 MHz in bandwidth; this trapped-ion version reaches past 1 GHz. The next concrete barrier is demonstrating this protocol on a multi-ion system where the motional modes couple to external fields of interest — moving from proof-of-concept on an internal motional mode to actual sensing of an external signal. For nanoscale NMR, the target is detecting single nuclear spins with sub-Hz linewidths in condensed matter environments. The obvious experiment not run: applying this protocol to sense an actual external field or nuclear spin signal, rather than the ion's own motional frequency. The honest read is (a) — different apparatus. A motional-mode demonstration is the natural first step because the experimenters have exquisite control over the target frequency. Coupling to an external analyte requires a different trap geometry or a hybrid system (e.g., ion near a surface with target spins). This is an engineering pivot, not a physics gap, and it's almost certainly the next paper.